Chiller and Cooling Tower Scrap: Tonnage, Tubes and Permits

Last updated · Reviewed by the Scrap Price Today editorial team

A big water-cooled chiller is mostly steel by weight, but its value is in the copper tubes inside the shells and in the refrigerant that has to come out first. Selection sheets for two 400- to 500-ton centrifugal chillers, published in a university engineering report, list shipping weights of about 16,300 and 19,700 pounds, refrigerant charges of 570 to 1,250 pounds, and evaporator and condenser bundles made of 0.025-inch copper tubes, 531 of them in one unit. By our estimate that's roughly 1,400 to 2,200 pounds of copper, worth something like $7,000 to $12,000 at the late-October US rate for No. 2 copper if it comes out clean. Cooling towers are the opposite story: mostly plastic fill, galvanized or stainless steel and sometimes treated wood, and on older towers, asbestos.

Chiller values today

Chiller metals and the copper estimate scrap value, computed at today's rates, updated Nov 23, 2026
Route or componentBasisNotesValue today (USD)
MeasurementWhat the figure is based onWhat changes itComputed from the live rate unless marked a reference
Copper tubes pulled clean from the bundles, #2 copperPer lbOne US yard board, late October 2026$5.30 to $5.30
Copper-aluminum coil from air-cooled chillersPer lbSame yard, late October 2026$2.25 to $2.25
Compressor and drive motors, electric motor gradePer lbMichigan yard average, 23 October 2026$0.25 to $0.25
Steel shells, tube sheets and base framePer lbSite steel reference; heavy plate once cut to size$0.15 to $0.15
Copper in a 400 to 500 ton chiller bundle, our estimateEach1,400 to 2,200 lb at the #2 rate if extracted clean$7,000 to $12,000
Metal reference: Shred steel $0.15 per pound. Rates shown are the site's tracked benchmarks, refreshed from the daily feed. Weights are typical published figures and vary by make and model. Rows marked as a reference are not futures-linked. Figures are indicative buyer ranges for the material described, not offers to buy.

The grade rows are dated yard prices; the steel row follows the site's live reference. The last row is our own estimate for a typical 400- to 500-ton centrifugal machine, explained below, and depends on getting the tubes out of their steel tube sheets.

Tonnage, weight and tubes

Chillers are sold by cooling capacity in tons, and their size follows. Trane's CenTraVac range alone runs from 200-ton machines to duplex units of nearly 4,000 tons. For the mid-size centrifugal chillers common in office buildings and hospitals, the selection sheets we found give a sense of what's inside:

ItemChiller AChiller B
Shipping weightabout 19,700 lbabout 16,300 lb
Refrigerant charge950 lb1,250 lb
Evaporator and condenser tubes0.025 in copper271 + 260 tubes, 0.025 in copper
Compressor, motor, starternot listed1,807 lb, 1,460 lb, 1,150 lb

We estimated the copper from Chiller B's tube count: 531 tubes of 3/4- to 1-inch diameter and 12 to 14 feet long, with 0.025-inch walls, works out to roughly 1,400 to 2,200 pounds once the internal enhancement is allowed for. That is a calculation, not a weighed figure. Bundles in chillers cooled by seawater are often copper-nickel rather than copper, which pays less, so check the nameplate or submittal before pricing a bundle.

The rest is steel: the evaporator and condenser shells, tube sheets, water boxes and the base frame. Shells are heavy plate and sell well once cut to size; prepared vs unprepared steel explains the difference. The compressor and motor go in as electric motors, around 25 cents a pound at Michigan yards in October.

Getting the copper out

Tubes are expanded into thick steel tube sheets at each end of the shell. A yard that takes a whole bundle will grade it as copper-bearing scrap with steel attached and pay far below the No. 2 rate. To get the full copper price, the tubes have to be cut or pulled free of the tube sheets and the steel kept out of the copper pile. That's industrial work, usually done by a demolition contractor or a specialist recycler with the right shears, so get offers both ways: for the bundle as is, and for clean tube after processing.

Air-cooled chillers are built differently. Their condenser coils are finned, either copper tube with aluminum fins or, on many newer units, all-aluminum microchannel, the same split covered in our rooftop unit scrap value guide.

Refrigerant: by far the biggest regulated item

A rooftop unit holds a few pounds of refrigerant; a centrifugal chiller can hold more than half a ton. Older machines may still contain R-11 or R-12, and many low-pressure chillers run on R-123, whose production for servicing existing equipment is scheduled to end in the US in 2030, which gives recovered R-123 real value to reclaimers. Federal Section 608 rules require that a certified technician recover the full charge before the chiller is dismantled, and the records should travel with the scrap. Don't let anyone cut into a chiller that hasn't been recovered and certified empty.

Cooling towers and their permits

A cooling tower is a different kind of job. The fill alone can weigh more than 50,000 pounds in a conventional air-conditioning tower, according to one manufacturer's patent filing, and nearly all of it is plastic that goes to landfill. The frame and casing may be galvanized steel, stainless steel, fiberglass, concrete or chemically treated wood. Only the metal pays: stainless basins and fan decks, galvanized frames, motors and gearboxes, and copper wiring.

Older towers can also hide asbestos. When one power station's mechanical-draft towers were taken down, the demolition contractor first had to remove 780 asbestos-cement louvers, about 30,000 square feet of transite, before the rest could be scrapped; the PVC pipe and fill went to landfill, while the concrete, steel and nonferrous metal were recycled. Under the federal asbestos NESHAP rules, a facility must be inspected for asbestos before demolition and the state or local agency notified in advance, so plan the survey before you plan the scrap sale. Treated wood from old towers needs its own disposal route, not a bonfire.

Copper prices for chiller tubes abroad

Pulled chiller tube is sold as No. 2 copper or its local equivalent. The most recent published prices we could verify:

CountryCopper priceWho published it, and when
United States$5.30 a lb, No. 2 copperOne US yard board, late Oct 2026
United Kingdom£7.78 a kg, No. 2 copper averageukmetalprices.co.uk, 20 Oct 2026
CanadaCAD 3.50–4.80 a lb, clean copperToronto yard guide, Aug 2026
AustraliaA$7–A$10 a kg, No. 2 or mixed copperAustralian yard price guide, 2026
India₹490–₹540 a kg, copper (Delhi)Indian scrap rate listing, May 2026 update
BangladeshNo dated 2026 price foundNone verified

Refrigerant and asbestos rules follow the same pattern elsewhere: certified technicians for refrigerant recovery under the UK's F-gas rules and Australia's ARCtick licensing, and asbestos surveys before demolition under national or state law. The Indian price is from May and the Australian one from a general 2026 guide, so both are older than the rest; Bangladesh has no verified figure. Country pages: United Kingdom, Canada, Australia, India, Bangladesh. Current copper grades are on our copper scrap price page, and cutting and rigging precautions in scrapping safety.

Basis for these figures

Chiller weights, refrigerant charges and tube specifications are from manufacturer selection sheets reproduced in a 2006 Penn State architectural engineering report, and the CenTraVac capacity range is from Trane. The copper weight and value are our calculation from those tube counts and are labelled as an estimate. Cooling tower details come from a manufacturer's patent filing and a published account of a power station tower demolition. Scrap prices are dated yard boards and published averages. Read about source selection in our editorial policy, and about live-row calculations in the methodology.